Stair Calculator: Rise, Run and Number of Steps
Enter the floor-to-floor height and the tread depth. You get the number of steps, the riser height, the run, the pitch and the stringer length, checked against US or UK limits.
Last reviewed
Riser height
7.714 in
14 risers and 13 treads of 10 in
- Total run
- 130 in
- Pitch
- 37.6°
- Stringer length (nose line)
- 169.01 in
- ✓ Riser height not more than 7¾ in
- ✓ Tread depth not less than 10 in
The checks are only for the limits shown. Headroom, nosing, handrails, guards, landings and local amendments also apply, and your building authority has the final say. Allow for the thickness of the finished floors at the top and bottom, which change the first and last rise.
How a staircase is laid out
Every stair starts with one measurement, the total rise: the vertical distance from the finished floor at the bottom to the finished floor at the top. Everything else follows from it.
- Number of risers = total rise ÷ the largest riser allowed, rounded up. Rounding up keeps each riser at or below the limit.
- Riser height = total rise ÷ the number of risers. Every riser in the flight should be the same.
- Number of treads = risers − 1. The top floor acts as the last step.
- Total run = treads × tread depth. This is how far the stair extends horizontally.
- Pitch = atan(riser ÷ tread), the angle of the line along the nosings.
- Stringer length = √(total rise² + run²), the length along the nose line. The board you cut the stringer from must be longer, to allow for the cut-outs and the ends.
The limits the calculator checks
US, International Residential Code, section R311.7.5 (the City of Boise’s handout of the section):
- Riser height not more than 7¾ inches.
- Tread depth not less than 10 inches.
- The greatest riser in a flight may not exceed the smallest by more than ⅜ inch, and the same for treads.
UK, Approved Document K (2013), Table 1.1, private stair:
- Rise from 150 to 220 mm.
- Going from 220 to 300 mm, measured from nosing to nosing.
- A maximum pitch of 42°.
- The normal relationship of the rise and going: twice the rise plus the going is between 550 and 700 mm.
Headroom, nosings, handrails, guards and landings are separate requirements and are not checked here.
Worked examples
US: a 108 inch rise (9 feet) with 10 inch treads. 108 ÷ 7.75 = 13.94, so 14 risers. Each riser is 108 ÷ 14 = 7.714 inches. There are 13 treads, so the run is 13 × 10 = 130 inches (10 feet 10 inches). The pitch is atan(7.714 ÷ 10) = 37.6°, and the stringer measures √(108² + 130²) = 169.01 inches along the nose line. It passes both limits.
UK: a 2,600 mm rise with a 250 mm going. 2,600 ÷ 220 = 11.8, so 12 risers of 216.7 mm. Eleven goings make a run of 2,750 mm. The pitch is 40.9°, which is under 42°, and 2 × 216.7 + 250 = 683.3 mm, inside 550 to 700 mm. It passes.
UK: a 2,700 mm rise with a 220 mm going. 2,700 ÷ 220 = 12.3, so 13 risers of 207.7 mm. The pitch is 43.4°, over the 42° limit, so a private stair fails. A deeper going, such as 250 mm, brings the pitch down.
Making it work
- Measure from finished floor to finished floor. Add the thickness of flooring at the top and bottom, or the first and last risers will be wrong.
- Choose the tread first if space is tight. A longer tread gives a gentler stair but needs more floor space.
- Add a riser to lower each one. In the first example, 15 risers instead of 14 gives 7.2 inches each, with a longer run.
- Keep every riser equal. Uneven risers are a common cause of trips, which is why the codes limit the variation in a flight.
Common mistakes
- Counting treads as risers. A flight has one fewer tread than risers.
- Rounding the number of risers down. The risers then exceed the limit.
- Forgetting the floor finish. A thick finished floor at the top or bottom changes a rise.
- Mixing units. The US check works in inches and the UK check in millimetres.
- Treating the result as approval. Building authorities apply the rules adopted locally, which may differ.
For other right-angle sums, try the right triangle calculator. To size flooring and covering for the area, use the flooring calculator and the square footage calculator.
How it is calculated
All of the arithmetic is exact decimal arithmetic. Heights are shown to three decimals in inches and one in millimetres, and the pitch to a tenth of a degree.
Frequently asked questions
How do I calculate the number of steps in a staircase?
Divide the total rise, the height from finished floor to finished floor, by the largest riser you are allowed, and round up. A 108 inch rise at 7¾ inches per riser is 13.9, so 14 risers, each 7.71 inches.
Why are there fewer treads than risers?
The top floor serves as the last step, so a flight with 14 risers has 13 treads. The run is the number of treads times the tread depth, so 13 treads of 10 inches make 130 inches.
What are the US limits for riser and tread?
IRC section R311.7.5 says the riser height is not more than 7¾ inches and the tread depth not less than 10 inches. The tallest riser in a flight may not exceed the shortest by more than ⅜ inch, and the same applies to treads.
What are the UK limits?
Approved Document K gives a private stair a rise of 150 to 220 mm and a going of 220 to 300 mm, with a maximum pitch of 42°. Its normal relationship is that twice the rise plus the going is between 550 and 700 mm.
What is the pitch of a stair?
The angle of the nose line to the horizontal, the inverse tangent of the riser divided by the tread. A 7.71 inch riser with a 10 inch tread gives atan(0.771) = 37.6°.
Does the calculator replace the building rules?
No. It checks the riser, the tread and in the UK the pitch and the rise-going relationship. Headroom, nosings, handrails, guards, landings and local amendments also apply, so confirm with your building authority before you build.
Related calculators
- Right Triangle CalculatorChoose what you know about the right triangle and enter it.
- Square Footage CalculatorAdd each part of the room or plot as a shape, say whether it is added or taken away, and measure in feet, inches, yards, metres or centimetres.
- Length ConverterConvert any length or distance.
- Cubic Yards CalculatorEnter each section of the job as a rectangle or a circle, with its depth, and add an allowance for waste.
- Flooring CalculatorEnter the length and width of each room, choose the layout, and say how much one box covers.
- Paint CalculatorEnter each room's length, width and ceiling height with its doors and windows, choose the coats and the coverage printed on the can.